  keysight technologies infiniium v-series oscilloscopes 8 to 33 ghz data sheet
02 | keysight | infiniium v-series oscilloscopes - data sheet table of contents achieve clarity faster with infiniium v-series oscilloscopes ???????????????????????????????????????????????????????????????????? 03 achieve clarify faster with the best-in-class infiniium v-series oscilloscopes ??????????????????????????????????????? 06 industrys best signal integrity ??????????????????????????????????????????????????????????????????????????????????????????????????????????????????? 08 industrys fastest mixed signal oscilloscope ????????????????????????????????????????????????????????????????????????????????????????????? 10 industrys leading hardware serial trigger ???????????????????????????????????????????????????????????????????????????????????????????????? 11 industrys most advanced and flexible 30-ghz probing system ????????????????????????????????????????????????????????????? 13 industrys most advanced probing system ???????????????????????????????????????????????????????????????????????????????????????????????? 14 industrys most comprehensive software ?????????????????????????????????????????????????????????????????????????????????????????????????? 16 achieve clarify faster - frequency domain performance ????????????????????????????????????????????????????????????????????????? 24 most advanced platform ????????????????????????????????????????????????????????????????????????????????????????????????????????????????????????????? 26 keysight infiniium oscilloscope portfolio ???????????????????????????????????????????????????????????????????????????????????????????????????? 27 infiniium v-series ordering configuration ?????????????????????????????????????????????????????????????????????????????????????????????????? 28 ordering configuration ???????????????????????????????????????????????????????????????????????????????????????????????????????????????????????????????? 33 infiniium v-series performance characteristics ????????????????????????????????????????????????????????????????????????????????????????? 34 evolving since 1939 ????????????????????????????????????????????????????????????????????????????????????????????????????????????????????????????????????? 47
03 | keysight | infiniium v-series oscilloscopes - data sheet achieve clarity faster with infiniium v-series oscilloscopes groundbreaking oscilloscope technology the keysight technologies, inc ? infiniium v-series oscilloscopes incorporate innovative technology designed to deliver superior measurements ? whether you are testing multiple high-speed serial lanes or a massive parallel bus, the new 12 ? 5 gb/s, industrys longest 160-bit hardware serial trigger and worlds fastest 20 gsa/s digital channels will provide timely validation and debug ? our oscilloscopes low-noise front end technology, advanced infiniimax iii/iii+ series probes and revolutionary voltage termination adapter provide up to 33 ghz performance with the industrys best signal integrity ? together with the broadest software solution coverage, the v-series helps you achieve clarity faster in your design characterization to ensure your product ships on time ? fastest analysis and enhanced usability we put the groundbreaking oscilloscope technology in an innovate industrial design frame with a standard 500 gb removable solid state drive and high-powered motherboard for fastest analysis, capacitive 12 ? 1 display for multi-touch usability and usb 3 ? 0 ports for fast data offload speed ? coupled with the next-generation infiniium user interface, the v-series makes displaying, analyzing and sharing information much easier ? it is the first user interface to take advantage of multiple displays and touch screens ? it features up to 8 waveform windows with up to 16 grids in each of them, allowing 128 simultaneous viewing spaces ? dso models dsa models mso models analog bandwidth sample rate max memory bandwidth upgradability 4 analog channels 4 analog channels 4 analog channels + 16 digital channels 2 channels 4 channels 2 channels 4 channels 4 channels dsov334a dsav334a msov334a 33 ghz 16 ghz 80 gsa/s 40 gsa/s 2 gpts yes. each model is upgradable to each higher bandwidth step or the max bandwidth of 33 ghz. dsov254a dsav254a msov254a 25 ghz 16 ghz 80 gsa/s 40 gsa/s 2 gpts dsov204a dsav204a msov204a 20 ghz 16 ghz 80 gsa/s 40 gsa/s 2 gpts dsov164a dsav164a msov164a 16 ghz 16 ghz 80 gsa/s 40 gsa/s 2 gpts dsov134a dsav134a msov134a 13 ghz 13 ghz 80 gsa/s 40 gsa/s 2 gpts dsov084a dsav084a msov084a 8 ghz 8 ghz 80 gsa/s 40 gsa/s 2 gpts
04 | keysight | infiniium v-series oscilloscopes - data sheet achieve clarity faster with infiniium v-series oscilloscopes (continued) industrys most advanced probing system the infiniimax iii and iii+ probing systems provide unmatched signal fidelity and bandwidth performance up to 30 ghz to meet todays high-speed signal probing requirements ? C lowest noise and flattest frequency response C unique s-parameters stored in each probe, automatically downloaded to the scope for correction C precisionprobe for most accurate correction to the probe tip C infiniimode feature allows differential, single-ended and common mode measurements without probe reconnection C first magnetically engaged probe for secure connection C lowest-noise active voltage termination adapter C industrys only bandwidth upgradable probes keysights proprietary and custom front-end technology yields the industrys lowest noise floor and jitter measurement floor of real-time oscilloscope hardware available today ? infiniium v-series low-noise front end and the revolutionary voltage termination adapter provide the industrys best signal integrity ?
05 | keysight | infiniium v-series oscilloscopes - data sheet industrys best signal integrity for superior measurement accuracy the infiniium v-series family has the best-in-class signal integrity real-time oscilloscopes in the industry, delivering the most margin for your design validation ? they are ideal for spectral analysis of transients and wideband rf applications ? C true analog bandwidth to 33 ghz C lowest noise floor (2 ? 10 mv at 50 mv/div, 33 ghz) C lowest intrinsic jitter (100 fs) C highest effective number of bits (enob) values in excess of 5 ?5 C flattest frequency magnitude and phase response C spurious free dynamic range (sfdr) exceeding 50 dbc industrys most comprehensive software solution the v-series has the deepest and broadest range of software solutions to accelerate understanding of your signal performance from fundamental analysis to debug and compliance ? C analysis tools including jitter separation (dual-dirac, tail-fit, buj), eye-diagram, advanced de-embedding, ffe/ctle/ dfe equalizations and crosstalk analysis C worlds fastest digital channels, ideal for ddr4/lpddr4 trigger and decode as well as parallel bus validation C debug with industrys longest 160-bit, 12 ? 5 gb/s hardware serial trigger, prbs error detector and zone touch trigger C compliance software and technical expertise for high-speed standards (usb 3 ? 1, pcie ? gen 4, hdmi 2 ? 0, mipi ? , ethernet 100g, pam-4, etc ? ) for highest measurement confidence achieve clarity faster with infiniium v-series oscilloscopes (continued)
06 | keysight | infiniium v-series oscilloscopes - data sheet achieve clarify faster with the best-in-class infiniium v-series oscilloscopes 33 ghz true analog bandwidth and 80 gsa/s sample rate with ultra low-noise, intrinsic jitter and highest enob ? find rare events with the industrys longest 160-bit, 12 ? 5 gb/s hardware serial trigger and prbs error detector ? increase your productivity with the next-generation infiniium user interface, optimized for multiple displays and up to 128 simultaneous viewing spaces ? enhance your visual and touch experience with a 12 ? 1 xga (1024 x 768) high resolution capacitive touch screen ? identify anomalies easily with a 256-level intensity-graded or color-graded persistence display that provides a three-dimensional view of your signals ? support remote control over ethernet, gpib and usb interfaces ? remote programming allows oscilloscope and software automation ? lxi class c compliant, web-interface and matlab enabled ? correct insertion loss and skew of your test setup with precisionprobe ? the oscilloscope generates an edge of 12 ps rise time to enable tdt calibration ? capture the longest signal trace of up to 25 ms at 80 gsa/s sample rate using highest 2 gpts of acquisition memory ? trigger, analyze and debug your parallel bus with worlds fastest digital channels ? decode cutting-edge ddr4 and lpddr4 protocol memory buses ?
07 | keysight | infiniium v-series oscilloscopes - data sheet new industrial design and front panel layout that enhances user experience and operation of the oscilloscope ? save screen button provides quick access to capture oscilloscope waveform and analysis screenshots ? customizable multipurpose key allows you to customize its function to make your favorite measurements, execute a script, save waveforms or load a setup ? access the marker and change the positions quickly through the dedicated marker controls ? quick access to fine control by pressing the horizontal and vertical knobs ? five usb 3 ? 0 host and device ports at the front and back panel for data offload speed ? additional usb 2 ? 0 ports provide connectivity to your usb keyboard, mouse and other peripherals ? standard 500 gb removable solid state drive improves processing speed and enhances data security ? 1 tb storage option is available ? threaded 3 ? 5 mm rf connectors with convenient torque mechanism ensures the most reliable signal integrity and consistent 8 in ? lbs ? connection ? the autoprobe ii interface provides a robust interface for the infiniimax iii and iii+ probing system ? external 10-mhz reference clock input and output for precise timebase synchronization with more than one oscilloscope, rf instruments or logic analyzers ?
08 | keysight | infiniium v-series oscilloscopes - data sheet groundbreaking oscilloscope technology for highest measurement accuracy whether you are deploying emerging high-speed bus technology, identifying spectral content of wideband rf signals or analyzing transient physical phenomena, you need the truest representation of your signal under test ? keysight invests in leading-edge technology to bring you the highest real-time oscilloscope measurement accuracy available today ? indium phosphide integrated circuits ? front-end multi-chip module ? acquisition board ? industrys best signal integrity keysight utilizes a proprietary indium phosphide (inp) integrated circuit process to design the key technology blocks to deliver high-bandwidth performance, ultra-low noise and high-voltage signal input ? this process is used in the pre-amplifier, trigger, sampling, adc and probe amplifier integrated circuit design ? not only does this mean you are purchasing the best oscilloscope on the market today, but you can also count on technology leadership from keysight in the future ? infiniium v-series front-end multi-chip module integrates the pre-amplifier, trigger and sampling technology blocks using a proprietary cutting-edge packaging technology ? based on fine-line microcircuit processes and extensive experience with rf design, keysight developed a front-end that provides excellent high-frequency electrical properties along with superior heat dissipation ? the unique technology includes a quasi-coaxial path in the packaging to ensure signal shielding and delivers a high-speed clock to the sampler chip for the most accurate sampling time base ? all technology blocks, including the front-end, analog-to- digital converter (adc), memory controller, digital channels and hardware serial trigger, are meticulously laid out on the acquisition board with outstanding noise and coupling isolation ? time scale accuracy of 0 ? 1 parts per million after calibration is achieved through precise clock synchronization and distribution, as well as the use of a 10-mhz oven-controlled crystal oscillator (ocxo) with 0 ? 1 ppm of accuracy ?
09 | keysight | infiniium v-series oscilloscopes - data sheet superior measurements oscilloscope bandwidth allows signal rise times to be more accurately depicted ? the oscilloscope noise floor directly impacts the y-axis voltage placement of each signal data point ? the v-series combines superiority in these characteristics with extremely low sample clock jitter (< 100 fs) ? this ensures the lowest possible contribution to jitter measurements ? in addition, the v-series has the industrys deepest memory of up to 2 gpts, allowing you to resolve low frequency jitter components in a single measurement ? keysights oscilloscopes are constantly improving in measurement accuracy ? the latest innovation is an improved calibration routine that better aligns the sample points of the analog-to-digital converter ? the improved calibration results in higher spurious free dynamic range (sfdr) and effective number of bits (enob) ? the sfdr is improved as much as 15 dbc depending on the carrier frequency ? higher sfdr is ideal for making rf and optical measurements where spectral purity is of the utmost importance ? improved sfdr and enob also means better jitter performance ? ultimately this means the v-series now features the highest sfdr and enob of any oscilloscope on the market ? ultra-low noise at 33-ghz full bandwidth (2 ? 10 mv at 50 mv/div) ? jitter measurement floor of less than 100 fs (80 fs with 30 ghz input sine wave) ? improved calibration increases the spurious free dynamic range by up to 15 dbc ? industrys best signal integrity (continued)
10 | keysight | infiniium v-series oscilloscopes - data sheet industrys fastest mixed signal oscilloscope worlds fastest 20 gsa/s digital channels, delivering best analog and digital performance todays designs require access to complex triggers and multiple instruments ? a mixed signal oscilloscope (mso) integrates traditional analog channels with 16 digital channels, providing up to 20 channels you can use at once ? keysight msos seamlessly integrate the familiar controls of an oscilloscope with the additional digital data acquisition and pattern recognition of a logic analyzer ? you can trigger across any combination of analog and digital channels, as well as decode the acquired data ? the mso has the ability to label each individual channel as part of a bus for decoding, saving hours of manual work ? with the fastest 20 gsa/s sample rate, it provides superior insight into low-speed serial and high-speed parallel bus interfaces ? mso optimized for ddr/lpddr2, 3, and 4 protocol triggering and decode the mso is specially targeted at ddr/lpddr2, 3 and 4 memory technologies, simplifying the complicated task of triggering, analyzing and debugging the parallel buses ? the additional digital channels mean you can probe at the various command signals to easily trigger on the different ddr commands such as read, write, activate, precharge and more ? ddr triggering makes read and write separation easy, providing fast electrical characterization, real-time eye analysis and timing measurements ? the ddr protocol decoder can decipher the ddr packets and provide a time-aligned listing window to search for specific packet information ? all of the above features come standard with the mso ? the mso is fully compatible with keysights 90-pin logic analysis connectors, making it easy to connect to your devices ? ddr3 test setup with mixed signal oscilloscope ? ddr3 protocol decode and write command trigger ? ddr3 write data burst eye-diagram analysis ?
11 | keysight | infiniium v-series oscilloscopes - data sheet industrys leading hardware serial trigger challenges identifying and debugging high-speed serial buses in todays high-speed serial application debug, it is not always easy to find errors that happen rarely or occasionally ? conventional oscilloscopes usually have limitations because of the long dead time between acquisitions, which cause infrequent errors or events to be missed ? furthermore, it is becoming more difficult to identify and debug the root cause of design problems, whether it is physical or protocol layer related ? industrys longest 160-bit sequence and sixteen- 8b/10b symbols hardware serial trigger the infiniium v-series 12 ? 5 gb/s hardware serial trigger with the industrys longest 160-bit sequence provides an effective event trigger to find and debug the most challenging problems in your design ? you can specify to trigger on bit 1 (high), 0 (low) and x (dont care) conditions when searching for a specific event ? the 160-bit sequence length is critical to trigger at the longest symbol in an application such as usb 3 ? 1 and pci express ? gen 3 symbols that are 132-bit and 130-bit long ? if the trigger bit sequence is insufficient, you will not be able to reliably trigger on an event you want to identify, making the debug process more challenging ? the hardware serial trigger also provides 8b/10b triggering of up to 16 symbols of k and d codes ? since the 8b/10b symbols can be transmitted with either disparity to maintain the dc-balanced on the line, the hardware serial trigger is designed to trigger on both disparities so you do not miss an event ? in additional, the v-series can decode the data packet at the application level such as pcie gen 3, usb 3 ? 0 and sata packets, providing deeper protocol insight into the application ? when there is an error, you can now go in and debug the issue whether it is related to the physical layer, where the signal integrity is corrupted, or protocol layer, where the data is incorrectly transmitted ? v-series hardware serial trigger finds a pci express gen 3 compliance ordered set symbol that is 130-bit long (pcie gen 3 uses 128b/130b encoding) ? the v-series 8b/10b hardware triggers at 16 k and d symbols of the sata signal ? the software protocol decoder further decodes the symbols into higher-level data packets such as the sata align packets ?
12 | keysight | infiniium v-series oscilloscopes - data sheet industrys leading hardware serial trigger (continued) industrys only 12 ? 5 gb/s hardware serial trigger with ssc tracking at oscilloscope channel the infiniium v-series hardware serial triggers speed covers most common high-speed serial bus rates starting from 480 mb/s up to 12 ? 5 gb/s, which include usb 2 ? 0, usb 3 ? 1, pci express gen 3, hdmi 2 ? 0 and sas-3 applications ? most of these applications also support spread spectrum clocking (ssc) where the high-speed signal is modulated, and the v-series hardware serial trigger is able to track the ssc at the oscilloscope input channel or with the use of an external reference clock input ? the hardware serial trigger will recover and generate a sub-rate clock when locked to the signal ? external reference clock input is one of the methods to enable ssc tracking by the hardware serial trigger ? prbs error detector triggers on a bit error in the prbs-15 signal ? an eye view plot (bottom left) is provided to show the quality of the signal received by the hardware serial trigger ? the hardware serial trigger works when there is enough eye opening (blue area) to discern the bit value ? hardware serial trigger and infiniiscans software serial trigger provide up to 240-bit sequence trigger ? use with infiniiscans software serial trigger for up to 240-bit sequence trigger the hardware serial trigger can be combined with infiniiscans software event trigger to provide a two-stage trigger for up to 240-bit sequence ? this is particularly powerful for the v-series with its deep acquisition memory (up to 2 gpts), providing long trace capture of 25 ms at the high resolution sampling rate of 80 gsa/s ? the hardware first finds the 160-bit event condition and then uses infiniiscan for an additional 80-bit event trigger ? the infiniiscan event trigger is not limited to bit sequence search ? other search functions such as zone touch trigger allow you to visually draw zones on the oscilloscope display as a second stage trigger ? industrys first prbs error detector the prbs error detector can trigger and display the bit error of the prbs-7, 15, 23, and 31 signals ? it identifies the error when the pattern does not match the expected prbs pattern that has been set in the oscilloscope ? when the next error happens, the oscilloscope will replace the display with the next bit error ? this allows you to discover if the error is related to the bit pattern, which is related to inter-symbol interference (isi) ? the hardware serial trigger provides an eye view plot to show the signal quality of the signal received ?
13 | keysight | infiniium v-series oscilloscopes - data sheet to take advantage of your investment in a high-bandwidth oscilloscope, you must have a probing system that can deliver high performance measurements ? infiniimax iii and iii+ probing systems provide up to 30 ghz of bandwidth, delivering unrivaled performance and real-world usability ? the infiniimode feature allows convenient measurement of differential, single-ended and common mode signals with a single probe tip C without reconnecting the probe from its connection point ? industrys only fully-integrated probe amplifier with unique s-parameter correction each individual infiniimax iii and iii+ probe amplifier stores its unique s-parameters and is automatically downloaded to the oscilloscope when connected for probe response correction ? the s-parameters of the various probe heads are also applied to further flatten the probes magnitude and phase response for better measurement accuracy ? traditionally, probe correction uses a nominal model based on a typical probe amplifier instead of the specific amplifier ? generally, the biggest variations between probing systems are a result of the probe amplifier ? the ability to correct a specific probe amplifiers response results in a more accurate probe correction, which yields a more accurate measurement ? industrys only upgradable probes purchase the probing performance you need today with confidence that you can expand your performance in the future with infiniimax iii bandwidth-upgradable probes ? upgrade to higher performance at a fraction of the cost ? the infiniimax iii and iii+ 30-ghz probing system includes accessories to enable probing with a zif tip, browsing or connecting to 2 ? 92 mm/3 ? 5 mm/ sma inputs ? the infiniimax iii and iii+ probing system uses the same inp technology that enables high-bandwidth and low-noise oscilloscope measurements ? industrys most advanced and flexible 30-ghz probing system
14 | keysight | infiniium v-series oscilloscopes - data sheet for more information about infiniimax iii and iii+ probes matching the performance of your infiniium oscilloscope, see the infiniimax iii and iii+ probes and accessories data sheet with the keysight publication number 5990-5653en ? industrys lowest-noise active voltage termination adapter the n7010a active termination adapter provides a low noise single-ended cabled measurement solution with 50 ? voltage termination (v term ) up to 30 ghz bandwidth ? the adapter is optimized for low amplitude signal measurements with its high signal-to-noise-ratio and low noise performance ? the range of the v term can be set to 4 v, which is ideal for applications such as hdmi, displayport, mhl and mipi m-phy ? , which require voltage termination ? the adapter is compatible with 2 ? 92 mm, 3 ? 5 mm, and sma connectors, as well as a smp connector when an adapter is used ? industrys first magnetically-engaged probe head and tip the n2848a/49a quicktip offers the industrys first magnetically-engaged probe head and tip for a quick and secure connection ? the n2848a quicktip probe head quickly snaps to the n2849a probe tip, utilizing magnets to connect to the two sides of the differential signal and ground ? multiple n2849a probe tips can be installed on a board or device, allowing quick and reliable measurement of many probe points ? the quicktip supports infiniimode probing when used with the infiniimax iii+ probe amplifier and supports differential probing with the infiniimax iii probe amplifier ? n7010a active termination adapter provides a low noise single-ended cabled measurement solution with 50 ? voltage termination (v term ) up to 30 ghz bandwidth ? the n2848a/49a is the industrys first magnetically-engaged probe head and tip for a quick and secure connection ? industrys most advanced probing system
15 | keysight | infiniium v-series oscilloscopes - data sheet turn your v-series into a time-domain transmission (tdt) instrument to quickly characterize and compensate any probes, cables or measurement setup ? precisionprobe technology turns your oscilloscope into the ultimate characterization tool ? it provides quick characterization of your entire measurement setup (including probes, cables and switches) without the need for extra equipment ? precisionprobe takes advantage of the infiniium v-series 12 ps edge to characterize and compensate for loss on the measurement system ? precisionprobe compensation technology: C creates custom probe transfer function (vout/vin) C characterizes probed system transfer function (vout/vin = vout/vsrc) C removes unwanted cable insertion loss (s21) now every probe and cable in the system can have the exact same frequency response without measurement variation caused by probe or cable difference ? you can properly characterize custom probes as well ? when you combine infiniimax iii and iii+ probes with switches between the amplifier and the probe head, precisionprobe allows full correction for each probes path ? for increased accuracy, precisionprobe advanced with faster edge (6 ps) is available ? the magnitude and phase response of a cable corrected using precisionprobe ? keysight uses indium phosphide process to produce a 12 ps edge step response, ideal for characterizing cable and probe frequency response ? industrys most advanced probing system (continued) pcie gen 3 measurement improvement with precisionprobe root complex eye height with standard calibration eye height with precisionprobe margin improvements 5 gt/s 306.6 mv 348.33 mv 13.6% 8 gt/s 96.82 mv 106.01 mv 9.4%
16 | keysight | infiniium v-series oscilloscopes - data sheet hardware-accelerated rendering the infiniium v-series renders the waveform in real time through the oscilloscope hardware so it does not increase processing time ? rendered waveforms are obtained quickly, which saves you much time compared to processing done in software ? circuit models to define your setup the infiniisim waveform transformation toolset provides a graphical user interface for you to define your measurement system, including an arbitrarily complex system ? select from the application preset for different topologies ? define the circuit blocks with open, through, rlc circuit, or s-parameter files ? model reflections with the infiniisim waveform transformation toolset, you can transform signals with confidence, whether you are inserting or removing channel elements or relocating the measurement point ? infiniisim lets you model up to 27 different elements or s-parameters at once, as well as the interaction between them ? infiniisim is the only toolset with the ability to model more than one element including reflection model ? the v-series provides its own input reflection (s 11 ) in all modeling ? model your system with as much detail as you need infiniisim features the model setup that best matches your design ? whether it is a simple single-element model or an advanced general-purpose model with up to 27 elements in the link, you can perfectly model your design and simulate the exact probing point you want ? the most advanced waveform transformation software helps you render (embed/de-embed) waveforms anywhere in your design ? the infiniisim waveform transformation toolset provides the most flexible and accurate means to render waveforms anywhere in your design ? the highly-configurable system modeling enables you to de-embed the effects of unwanted channel elements, embed waveforms with channel models, view waveforms in physically improbable locations and compensate for loading of probes and other circuit elements ? infiniisim allows embedding and de-embedding of up to 27 different elements or s-parameter models at once to meet your most demanding requirements ? infiniisim renders the waveform through hardware acceleration ? industrys most comprehensive software
17 | keysight | infiniium v-series oscilloscopes - data sheet serial data equalization opens the closed eye using ctle and dfe methods ? draw up to eight must intersect or must not intersect zones to trigger on a specific event and condition ? open tightly shut eyes with equalization serial data equalization for the infiniium v-series provides fast and accurate equalization using feed-forward equalization (ffe), continuous time linear equalization (ctle) and decision feedback equalization (dfe) modeling in real time ? the tool allows you to use a combination of the equalization, which is found in actual designs ? serial data equalization software allows you to input your own equalizer settings and tap values that are used in your design, allowing you to simulate the eye opening in your receiver ? if you prefer, the software can find the optimal tap values for you as well, which you can use as reference for your designs ? powerful and flexible software trigger the infiniiscan software is a powerful tool for identifying signal integrity issues that hardware triggering is unable to find in your design ? this innovative tool scans through thousands of acquired waveforms per second to help you isolate signal anomalies, saving you time and improving your designs ? it includes an 80-bit sequence trigger to find events of interest ? infiniiscans zone touch trigger allows you to draw up to eight must intersect or must not intersect zones on the oscilloscope display to visually determine the event-identify condition ? if you can see the event of interest on the screen, the zone touch trigger can be used to quickly and easily isolate it, saving significantly more time than complicated hardware triggers ? other triggers include non-monotonic edge, measurement limit search, runt and pulse width ? industrys most comprehensive software (continued)
18 | keysight | infiniium v-series oscilloscopes - data sheet real-time eye and clock recovery serial data analysis (sda) software provides flexible clock recovery including 1st- and 2nd-order pll, explicit and constant clock ? with a stable clock, you can look at real-time eyes of transition and non-transition bits ? v-series oscilloscopes with sda software also provide a unique view of bits preceding an eye ? measurement trends and jitter spectrum the ezjit tool helps you quickly analyze the causes of jitter ? measurement trends allow you to see deeper views of factors affecting measurements ? jitter spectrum is a fast method to find the causes of jitter ? the trend also allows you to characterize spread spectrum clock (ssc) if it meets frequency and modulation deviation requirements ? two ways to separate jitter ezjit plus comes with two ways to separate jitter: the industry- standard spectral method and the emerging tail-fit method ? both methods allow for simple separation of rj and dj, but the tail-fit method provides jitter separation in the unique case of non- symmetrical histograms and aperiodic bounded uncorrelated jitter (abuj) ? unique rj/dj threshold view ezjit plus also provides a unique spectral view of the jitter spectrum with the threshold drawn on the chart ? the spectral view provides insight into the decision point of the separation and allows for narrow or wide, tail-fit, or dual-dirac ? tools to determine the correct settings sda, ezjit, and ezjit plus come with an array of visual tools to make analyzing the data simple and ensure that the correct settings are chosen for difficult design decisions ? for example, the improved bathtub curve is a helpful visual tool to determine which jitter separation method best fits the data ? gain insight into the causes of signal jitter to ensure your design has high reliability with faster edge speeds and shrinking data-valid windows in todays high-speed digital designs, insight into the causes of jitter has become critical for success ? using ezjit and ezjit plus jitter analysis software, the infiniium v-series helps you identify and quantify jitter components that affect the reliability of your design ? time correlation of jitter to the real-time signal makes it easy to trace jitter components to their sources ? additional compliance presets and a setup wizard simplify and automate rj/dj separation for testing against industry standards ? ezjit plus automatically detects embedded clock frequencies and repetitive data patterns on the oscilloscope inputs and calculates the level of data-dependent jitter (ddj) that contributes to the total jitter (tj) by each transition in the pattern, a feature unique to infiniium oscilloscopes ? extract measurement trend from the signal for ssc characterization ? multiple jitter analysis plots for enhanced visualization ? industrys most comprehensive software (continued)
19 | keysight | infiniium v-series oscilloscopes - data sheet more than your standard jitter package to efficiently determine root cause for any type of signal degradation in the amplitude domain, you must first determine whether the problem is caused by random or deterministic sources ? to accomplish this task, ezjit complete takes analysis techniques used in the time domain (jitter analysis) and extends them into the amplitude domain ? more than just an eye contour ezjit complete is an in-depth view into impairments related to signal levels C either logic ones or logic zeroes C deviating from their ideal positions ? existing eye-diagram tools simply provide a view of an eye contour but do not provide real measurement data other than nice graphics and eye contour ? ezjit complete uses separation techniques to allow each bit to be examined to determine correlated effects, as well as make multiple measurements on individual bits to determine uncorrelated effects ? use ffts to analyze the frequency domain and extract random components ? dual-dirac modeling techniques are also carried from the jitter domain and used in the interference domain ? key measurements with ezjit complete, the v-series oscilloscopes offer the following unique noise measurements: C total interference (ti) C deterministic interference (di) C random noise (rn) C periodic interference (pi) C inter-symbol interference (isi) C relative intensity noise (rin - dbm or db/hz) C q-factor industrys most comprehensive software (continued) discover signal anomalies in the amplitude noise domain of the waveform noise analysis with ezjit complete software for insight into the sources of noise in the signal ?
20 | keysight | infiniium v-series oscilloscopes - data sheet use you pc to view and analyze data away from your oscilloscope now you can do additional signal viewing and analysis away from your oscilloscope and target system ? capture waveforms on your oscilloscope, save them to a file, and recall the waveforms into keysights infiniium offline application on your pc ? view and analyze anywhere your pc goes take advantage of the large, high-resolution screens and multiple displays found in your office ? use familiar oscilloscope controls to quickly navigate and zoom in to any event of interest ? use auto measurements and functions for additional insight ? share scope measurements more easily across your team you can share entire data records instead of being limited exclusively to static screen shots ? collaborate with teams members who work in different locations ? create more useful documentation add up to 100 bookmark annotations and up to 20 simultaneous measurements on the oscilloscope display ? use features such as right-click and cut-and-paste to move screen images between applications, without ever having to save the image to a file ? access all advanced analysis capabilities infiniium offline includes a variety of upgrade options including serial decode upgrades for a variety of serial buses, jitter analysis and serial data analysis found in your oscilloscope ? industrys most comprehensive software (continued) infiniium offline software supports a wide array of infiniium applications ? use infiniium offline to find signal anomalies such as power supply coupling ? peak search capability makes infiniium offline a frequency domain tool ?
21 | keysight | infiniium v-series oscilloscopes - data sheet enhanced ffts view the infiniium v-series allows you to see frequency domain and time domain at the same time ? the standard spectral viewer includes fft controls such as start/stop, center frequency/span and resolution bandwidth (rbw) ? readout includes power and frequency axis annotation and a peak table ? envelope measurements and am demodulation envelope measurement tracks the outline and am demodulation of a burst signal ? this is required for applications such as near- field communication (nfc) and wireless charging applications ? add measurements such as rise time to the envelope function for characterization of the burst signal ? gated measurements and ffts the v-series supports gated math and analysis including ffts ? use any of the standard 16 independent gates to narrow measurements and fft computations to a specific time window ? drag the gate in the time domain, and see time correlated fft measurements for specified time periods ? the example at the right shows two simultaneous ffts ? industrys most comprehensive software (continued) enhanced frequency and time domain measurements peak readouts in the fft plot ? perform measurements in the area of interest through the gated function ? envelope detection of signal burst ?
22 | keysight | infiniium v-series oscilloscopes - data sheet compliance applications with deep standard technical expertise todays demanding environment means you have less time to understand the details of the technologies you are testing ? you also have less time to develop test automation software to increase measurement throughput and decrease time to market ? keysights compliance applications and expertise save you time and resources with measurement automation ? compliance applications are certified to test to the exact specifications of each technology standard ? if a test passes on the v-series in your lab, you can be assured that it will pass in test labs and plugfests worldwide ? keysight experts are on multiple technology boards and industry standards committees, and they help to define compliance requirements ? setup wizards combined with intelligent test filtering give you confidence that you are running the right tests ? comprehensive html reports with visual documentation and pass/fail results guarantee that critical information is retained ? check the v-series ordering configuration for supported standards ? test customization and switch automation the n5467b user-defined applications add-in provides you with the ability to add additional tests, instrument control and device control into the existing compliance applications ? the compliance applications can be controlled via the remote programming interface (standard feature) for test automation ? compliance applications on the v-series support a switch matrix, making testing simpler by automating test for each lane of a multi-lane bus ? typical testing requires reconnecting the oscilloscope each time you switch a lane, which increases test time and possible inaccuracies ? the v-series solves this problem by supporting a switch matrix through its compliance test ? simply connect the switch to the oscilloscope and all the lanes, and then press run to complete full testing of your entire device ? the compliance application fully supports precisionprobe and infiniisim software, giving you the ability to characterize and normalize every switch path to the device under test ? industrys most comprehensive software (continued) ddr4 and lpddr4 compliance application providing full electrical and timing characterization based on jedec specification ? test automation for multilane interface testing with no compromise on accuracy, which reduces test time and effort ? an infiniium 90000 x-series oscilloscope is shown above ?
23 | keysight | infiniium v-series oscilloscopes - data sheet decodes more than 20 protocol standards the infiniium v-series oscilloscopes come with more than 20 protocol decoders for decoding high-speed serial bus and low-speed serial interface protocols ? the list includes the industrys only 64b/66b decoder used by ethernet 10gbase-kr standard and multilane mipi decode ? the v-series protocol decoders feature time-correlated markers that let you easily move between the listing window and the waveform ? it generates crc value from the payload and compares the value with the embedded crc to verify if any bit error has occurred ? once an error is detected, you can further debug the problem, whether it is caused by physical or protocol issues ? multiple protocol decoders can be used at the same time with analog and digital channels ? they feature search and trigger capability that lets you scan through the waveform to find the trigger condition that interests you ? protocol decoders are available in the infiniium offline tool as well ? check the v-series ordering configuration for supported protocols ? combine v-series and matlab for even more analysis enhance the v-series with a seamless gateway to powerful matlab analysis functionality ? user-defined function software adds new analysis capabilities to the v-series beyond traditional math/analysis features ? now you have the freedom to develop your own math functions or filters using matlab and its signal processing toolbox ? with a seamless integration to matlab, the v-series allows you to display your math and analysis functions live on the oscilloscope screen, just like any other scope- standard functions ? industrys most comprehensive software (continued) packet decode and crc verification through the oscilloscope mipi unipro and ufs protocol decoders ? seamless integration of oscilloscope and matlab software enhances the analysis capability ?
24 | keysight | infiniium v-series oscilloscopes - data sheet wideband and multi-channel fft measurements for frequency domain measurements that require you to see more than 500 mhz of signal spectral bandwidth and multiple ffts simultaneously, the v-series offers wider bandwidth than spectrum analyzers and comes standard with 4 ports (channels) per instrument ? the v-series enables users to make wideband measurements up to 33 ghz and up to 16 simultaneous ffts ? you can analyze even higher bandwidth signals by combining the v-series with a down converter circuit ? achieve clarify faster - frequency domain performance use infiniium capture and analysis of radar bursts as shown in this orthogonal frequency-division multiplexing (ofdm) example ? using data acquired from v-series, vsa shows phase noise of 125 dbc/hz at 10 khz and 131 dbc/hz at 100 khz ? 1 ? s, v, and z-series 2 ch full bandwidth, 4 ch half bandwidth ? 2 ? up to 50 ghz carrier ? 3 ? 3 ? 6 ghz to 50 ghz carrier ? rf signal spectral bandwidth up to 4 1 1 1 1 0 mhz bw s-series 2 pxa 510 mhz 2 uxa 1 ghz 3 pxa + scope 1.2 ghz v-series z-series 510 mhz bw 1 ghz bw 8 ghz bw 13 ghz bw 32 ghz bw ... 63 ghz bw channels
25 | keysight | infiniium v-series oscilloscopes - data sheet trying to interpret traditional oscilloscope time-domain specifications can be challenging when trying to determine if a specific scope can be recommended for rf, w, and mmw measurements ? with correction filters, low-noise front end and spurious free dynamic range calibration, the v-series oscilloscopes can be used for wideband frequency domain applications ? v-series typical values (tested at 33 ghz bandwidth, 1 channel on one scope unless noted) sensitivity/noise density (1 mv/div; 38 dbm range) power spectral density measurement at 1.0001 ghz, 1.0001 ghz center frequency, 500 khz span, and 3 khz rbw 159 dbm/hz noise figure (derived from measurement above) +15 db signal-to-noise ratio/dynamic range (1 dbm, 1 ghz input carrier, 0 dbm scope input range) 1 ghz center frequency, 100 mhz span, 1 khz rbw, measurement at +20 mhz from center +111 db absolute amplitude accuracy (0 to 30 ghz) 0.5 db deviation from linear phase (0 to 33 ghz) 3 deg phase noise (at 1 ghz) 10 khz offset 100 khz offset 125 dbc/hz 131 dbc/hz evm (802.121 2.4 ghz carrier, 20 mhz wide, 64 qam) 47 db (0.47%) spurious responses (4.6 dbm input signal, 4 dbm input range) spurious free dynamic range (sfdr) 1 ghz, 4.6 dbm signal present at input, fft = 5 ghz span, 3 ghz center, 100 khz rbw +67 db 2nd harmonic distortion 1 ghz input, 4.6 dbm, 5 ghz span, 3 ghz center, 100 khz rbw 51 dbc 3rd harmonic distortion 1 ghz input, 4.6 dbm, 5 ghz span, 3 ghz center, 100 khz rbw 51 dbc two-tone third-order intercept (toi) point 0 dbm input tones, 2.436 and 2.438 ghz, 2 mhz separation, 2.437 ghz center frequency, 10 mhz span, 30 khz rbw, 8 dbm range +26 dbm input match (s 11 ) (< 50 mv/div, 0 to 30 ghz, no attenuation) (> = 50 mv/div, 0 to 30 ghz, no attentuation) 15 db; 1.4 vswr 21 db; 1.2 vswr typical frequency domain characteristics for the infiniium v-series (not guaranteed, subject to change) ? using data acquired from the v-series, vsa shows an excellent third order intercept (toi) value of 26 dbm ? using data acquired from the v-series, vsa shows an error vector magnitude (evm) for ieee 802 ? 11 qam 64 of 0 ? 47% ? achieve clarify faster - frequency domain performance (continued)
26 | keysight | infiniium v-series oscilloscopes - data sheet most advanced platform standard features on v-series platform for the most advanced oscilloscope standard 500 gb removable ssd for fast boot up, increased reliability and enhanced security ? five usb 3 ? 0 ports provide fast data offload ? capacitive touch and touch-friendly user interface enhances the oscilloscope usability ? fast, reliable and secure storage the v-series features 500 gb removable ssd for C fast boot-up time C increased reliability C easy removal for secure environments powerful cpu and motherboard v-series includes an intel core i5 quad core processor with 16 gb of ddr3 ram for fast computations, even with advanced math and deep memory ? the i/o ports on the oscilloscope include C ethernet 10/100/1000base-t C 4 usb 3 ? 0 host ports (2 in front, 2 at the back) C 1 usb 3 ? 0 device port (1 at the back) C 3 usb 2 ? 0 host ports (1 in front, 2 at the back) C displayport and vga video out ? drivers support up to two simultaneous displays fast data offload for applications that require digitized waveforms to be offloaded, the v-series has fastest offload interfaces ? C usb 3 ? 0 for up to 200 mb/s data offload C ethernet 1000base-t for up to 80 mb/s offload touch-screen innovation v-series oscilloscopes incorporate a capacitive touch screen ? in addition, infiniium software includes a large number of touch- friendly enhancements including handles, enlarged touch fields when touch is enabled, and gestures (multi-touch) ?
27 | keysight | infiniium v-series oscilloscopes - data sheet keysights infiniium oscilloscope lineup includes bandwidths from 500 mhz to 63 ghz ? use the following selection guide to determine which best matches your specific needs ? all infiniium real-time oscilloscopes feature the following: C industrys best signal integrity for each family series C industrys most advanced probing system C industrys most comprehensive software solutions infiniium series s-series 90000a series v-series z-series available bandwidths 500 mhz, 1 ghz, 2.5 ghz, 4 ghz, 6 ghz, 8 ghz 2.5 ghz, 4 ghz, 6 ghz, 8 ghz, 12 ghz, 13 ghz 8 ghz, 13 ghz, 16 ghz, 20 ghz, 25 ghz, 33 ghz 20 ghz, 25 ghz, 33 ghz, 50 ghz, 63 ghz maximum upgradable bandwidth 8 ghz 13 ghz 33 ghz 63 ghz maximum sample rate 20 gsa/s 40 gsa/s 80 gsa/s 160 gsa/s maximum memory (2-channel) 800 mpts 1 gpts 2 gpts 2 gpts standard memory (2-channel) 100 mpts 40 mpts 100 mpts 100 mpts standard memory (4-channel) 50 mpts 20 mpts 50 mpts 50 mpts channel inputs 50 ? and 1 m? 50 ? 50 ? 50 ? connector type precision bnc (f) precision bnc (f) 3.5 mm (m) 3.5 mm (m) (33 ghz input) 1.85 mm (m) (> 33 ghz input) connector mate bnc (m) bnc (m) sma (f), 2.92 mm (f) sma (f), 2.92 mm (f) (33 ghz input) 2.4 mm (f), 1.85 mm (f) (> 33 ghz input) mso models yes no yes 2 no hardware serial trigger option no no yes 1, 2 no supported infiniimax probe series infiniimax i infiniimax ii infiniimax iii+ infiniimax i infiniimax ii infiniimax iii+ infiniimax iii/iii+ infiniimax i/ii with n5442a adapter infiniimax iii/iii+ infiniimax i/ ii with n5442a adapter 1 ? trigger at a maximum 160-bit sequence or sixteen 8b/10b symbols ? works only on channel 1 ? 2 ? either mso or hardware serial trigger option can be added to the oscilloscope ? keysight infiniium oscilloscope portfolio
28 | keysight | infiniium v-series oscilloscopes - data sheet get the most out of your oscilloscope investment by choosing options and software for your most common tasks ? configure your infiniium v-series oscilloscope in three easy steps ? 1 ? choose your oscilloscope, memory and options oscilloscope main-frame oscilloscope models 1 analog bandwidth sample rate dso models(4 analog channels) dsa models(4 analog channels) 2 ms o models(4 analog channels + 16 digital channels) 2 channel 4 channel 2 channel 4 channel dsov334a dsav334a msov334a 33 ghz 16 ghz 80 gsa/s 40 gsa/s dsov254a dsav254a msov254a 25 ghz 16 ghz 80 gsa/s 40 gsa/s dsov204a dsav204a msov204a 20 ghz 16 ghz 80 gsa/s 40 gsa/s dsov164a dsav164a msov164a 16 ghz 16 ghz 80 gsa/s 40 gsa/s dsov134a dsav134a msov134a 13 ghz 13 ghz 80 gsa/s 40 gsa/s dsov084a dsav084a msov084a 8 ghz 8 ghz 80 gsa/s 40 gsa/s all models come with front cover, power cord, keyboard, mouse, calibration cable, esd wrist strap and (5) coax adapters 3 ? the 8 and 13 ghz models come standard with two n5442a precision bnc adapters ? oscilloscope memory depth 4 acquisition memory depth upgrade option number on new oscilloscope 50 mpts/channel memory standard 100 mpts/channel memory 5 dsov000-100 200 mpts/channel memory dsov000-200 500 mpts/channel memory dsov000-500 1 gpts/channel memory dsov000-01g 2 gpts/channel memory dsov000-02g options description option number on new oscilloscope hardware serial trigger 6 dsov000-810 mso with additional 16 digital channels 6 standard on mso models 1 tb removable solid state drive (ssd) with windows 7 dsov000-801 gpib card-interface dsov000-805 performance verification and deskew fixture dsov000-808 stack mount kit option for stacking two frames n2117a rack mount kit n5470a ansi z540 compliant calibration dsov000-a6j calibration + uncertainties + guardbanding (accredited) dsov000-amg dsa option for mso models 7 msov000-dsa testmobile scope cart 1180CZ 1 ? dsa models come standard with 100 mpts/channel, ezjit complete, and serial data analysis ? 2 ? oscilloscope 8, 13, and 16 ghz models come with 3 ? 5 mm female-to-female adapters rated to 25 ghz (part number 1250-3758) ? all other models come with 3 ? 5 mm female-to-female adapters rated to 35 ghz (part number 5061-5311) ? 3 ? memory depth per channel when 4 channels are turned on ? 4 ? dsa models come with 100 mpts/channel standard ? 5 ? either mso or hardware serial trigger option can be added to the oscilloscope ? upgrade is not available when the oscilloscope already has the mso or hardware serial trigger installed ? 6 ? available for mso models only ? dsa option comes standard with 100 mpts/channel, ezjit complete, and serial data analysis ? infiniium v-series ordering configuration
29 | keysight | infiniium v-series oscilloscopes - data sheet 2 ? choose your probes and accessories probe amplifier description model number 30 ghz infiniimax iii probe amplifier n2803a 25 ghz infiniimax iii probe amplifier n2802a 20 ghz infiniimax iii probe amplifier n2801a 16 ghz infiniimax iii probe amplifier n2800a 20 ghz infiniimax iii+ probe amplifier 1 n7003a 16 ghz infiniimax iii+ probe amplifier 1 n7002a 13 ghz infiniimax iii+ probe amplifier 1 n7001a 8 ghz infiniimax iii+ probe amplifier 1 n7001a probe head description model number 16 ghz quicktip probe head 2 n2848a quicktip probe tip (set of 4) 2 n2849a 16 ghz solder-in probe head n5441a 26 ghz solder-in probe head 2 n2836a 28 ghz zero insertion force (zif) probe head n5439a 200 ? zif tip for high sensitivity 3 n5447a 25 ghz pc board zif tip (for normal sensitivity) n2838a 30 ghz browser probe head n5445a browser tip replacement (set of 4) n5476a 28 ghz 3.5 mm/2.92 mm/sma probe head 2 n5444a probe adapter description model number 30 ghz voltage termination adapter (50 ? to 3.5 mm female-to-male connector) n7010a performance verification and deskew fixture n5443a precision bnc adapter (50 ? to 3.5 mm (female) to precision bnc (female) connector) n5442a sampling scope adapter (50 ? to 3.5 mm female-to-male connector) n5477a high impedance probe adapter (includes one n2873a passive probe) n5449a for more information about keysights infiniimax probes and accessories selection guide, view the keysight publication number 5968-7141en ? for more information about keysights infiniimax iii and iii+ probing system, view the data sheet with the keysight publication number 5990-5653en ? 1 ? with infiniimode technology, allowing you to switch to differential, single-ended, and common mode without adjusting probe tip connections ? 2 ? probe head that supports infiniimode connections ? 3 ? compatible only with infiniimax iii probe amplifier ? infiniium v-series ordering configuration (continued)
30 | keysight | infiniium v-series oscilloscopes - data sheet mso probes and accessories description model number single-ended flying lead set e5382b single-ended soft touch connectorless probe e5390a 1/2 size soft touch connectorless probe e5398a differential soft touch probe e5387a differential flying leads e5381a the mso is compatible with all keysight 90-pin cable connectors ? the n2815a mso/la cable comes standard with mso models or mso upgrade ? 3 ? choose your measurement-specific software measurement and analysis software description license type fixed floating factory-installed on new scope purchase or user-installed on existing scope user-installed transportable license server-based license ezjit complete jitter analysis n8823a-1fp n8823a-1tp n5435a-067 ezjit plus jitter analysis n540 0a-1fp n540 0a-1tp n5435a-001 ezjit jitter analysis e2681a-1fp e2681a-1tp n5435a-002 frequency domain analysis n8832a-001 high-speed sda and clock recovery e2688a-1fp e2688a-1tp n5435a-003 infiniiscan software triggering n5414b-1fp n5414b-1tp n5435a-004 infiniisim advanced signal de-embedding n5465a-1fp n5465a-1tp n5435a-027 infiniisim basic signal de-embedding n5465a-3fp n5465a-3tp n5435a-026 matlab - basic digital analysis n8831a-001 matlab - standard digital analysis n8831a-002 multiscope software - combines two scopes 1 n8834a-atp n5435a-085 multiscope software - combines up to five scopes 1 n8834a-btp n5435a-086 multiscope software - combines up to ten scopes 1 n8834a-ctp n5435a-090 pulse amplitude modulation (pam-4) analysis n8827a-1fp n8827a-1tp n5435a-077 precisionprobe calibration n2809a-1fp n2809a-1tp n5435a-044 serial data equalization n5461a-1fp n5461a-1tp n5435a-025 spectrum visualizer 64996a-1fp 64996a-1tp user-defined function n54 30a-1fp n54 30a-1tp n5435a-005 1 ? supports any combination of infiniium oscilloscope models with software 5 ? 50 and above ? infiniium v-series ordering configuration (continued)
31 | keysight | infiniium v-series oscilloscopes - data sheet 3 ? choose your measurement-specific software (continued) compliance test and validation software description license type fixed floating factory-installed on new scope purchase or user- installed on existing scope user-installed transportable license server-based license broadr-reach n6 467a-1fp n6 467a-1tp n5435a-062 ddr1 and lpddr1 u7233a-1fp u7233a-1tp n5435a-021 ddr2 and lpddr2 n5413b-1fp n5413b-1tp n5435a-037 ddr3 and lpddr3 u7231b-1fp u7231b-1tp n5435a-053 ddr4 and lpddr4 n6 462 a-1fp n6 462 a-1tp n5435a-056 displayport 1.2 u7232c-1fp u7232c-1tp n5435a-041 edp 1.4 n6 469a-1fp n6 469a-1tp n5435a-083 emmc n6 465a-1fp n6 465a-1tp n5435a-061 ethernet + eee 10/100/1000base-t n5392b-1fp n5392b-1tp n5435a-060 ethernet 10gbase-t u7236a-1fp u7236a-1tp n5435a-023 ethernet 10gbase-kr n8814b-1fp n8814b-1tp n5435a-059 ethernet 100gbase-cr10 n8828a-1fp n8828a-1fp n5435a-078 ethernet 100gbase-cr4 n8830a-1fp n8830a-1fp n5435a-080 ethernet 100gbase-kr4 n8829a-1fp n8829a-1fp n5435a-079 gddr5 u7245a-1fp u7245a-1tp hdmi 2.0 n5399c-1fp n5399c-1tp n5435a-070 mhl 3.0 n6460b-1fp n6460b-1tp n5435a-078 mipi d-phy sm u7238c-1fp u7238c-1tp n5435a-022 mipi m-phy u7249c-1fp u7249c-1tp n5435a-043 most n6466a-1fp n6466a-1tp n5435a-068 pci express gen4 n5393f-1fp n5393f-1tp n54 35a-112 sas-3 n5412d-1fp n5412d-1tp n5435a-073 sata gen 3 n5411b-1fp n5411b-1tp n5435a-028 sfp+ n6 468a-1fp n6 468a-1tp n5435a-074 usb 2.0 n5416a-1fp n5416a-1tp n5435a-017 usb 3.1 u724 3b-1fp u724 3b-1tp n5435a-075 usb hsic u724 8a-1fp u724 8a-1tp n5435a-042 uhs-i u7246a-1fp u7246a-1tp uhs-ii n6461a-1fp n6461a-1tp n5435a-052 user-defined application n5467b-1fp n5467b-1tp n5435a-058 thunderbolt n6 463b-1fp n6 463b-1tp n5435a-057 xaui n5431a-1fp n5431a-1tp n5435a-018 infiniium v-series ordering configuration (continued)
32 | keysight | infiniium v-series oscilloscopes - data sheet 3 ? choose your measurement-specific software (continued) protocol decode software description license type fixed floating factory-installed on new scope purchase or user- installed on existing scope user-installed transportable license server-based license 8b/10b (generic) - 1 - 1 - 1 64b/66b ethernet (10gbase-kr) n8815a-1fp n8815a-1tp n5435a-045 can/lin/flexray/can-fd n8803c-1fp n8803c-1tp n54 35c-103 ddr2/3/4 and lpddr2/3/4 - 2 - 2 - 2 ethernet 10base-t/100base-tx n8825a-1fp n8825a-1tp n5435a-088 i2c/spi n5391a-1fp n5391a-1tp n5435a-006 i 2 s protocol triggering and decode n8811a-1tp n8811a-1tp 105 jtag n8817a-1fp n8817a-1tp n5435a-038 mipi csi-3 n8820a-1fp n8820a-1tp n5435a-065 mipi digrf ? v4 n8807a-1fp n8807a-1tp n5435a-047 mipi d-phy n8802 a-1fp n8802 a-1tp n5435a-036 mipi lli n8809a-1fp n8809a-1tp n5435a-049 mipi rffe n8824a-1fp n8824a-1tp n5435a-072 mipi ufs n8818a-1fp n8818a-1tp n5435a-063 mipi unipro n8808a-1fp n8808a-1tp n5435a-048 spmi protocol trigger and decode n88 45a-1fp n8845a-2fp n54 35a-114 generic raw C nrz protocol decode - 1 - 1 - 1 generic raw C pam-4 protocol decode - 3 - 3 - 3 pcie 1 and 2 n5463a-1fp n5463a-1tp n5435a-032 pcie 3 n8816a-1fp n8816a-1tp n5435a-046 rs-232/uart n5462a-1fp n5462a-1tp n5435a-031 sata n8801a-1fp n8801a-1tp n5435a-035 ssic n8819a-1fp n8819a-1tp n5435a-064 svid n8812 a-1fp n8812 a-1tp n5435a-054 usb 2.0 n5464a-1fp n5464a-1tp n5435a-034 usb 3.0 n8805a-1fp n8805a-1tp n5435a-071 1 ? standard on dsa models or with high-speed sda option ? 2 ? standard on mso models or with mso upgrade ? 3 ? requires pam-4 app and sda option (firmware 6 ? 0 and up) ? infiniium v-series ordering configuration (continued)
33 | keysight | infiniium v-series oscilloscopes - data sheet upgrade your existing oscilloscope bandwidth upgrades description option number for existing oscilloscopes (post-sale) bandwidth upgrade to 13 ghz dsov13gbw bandwidth upgrade to 16 ghz 1 dsov16gbwu bandwidth upgrade to 20 ghz 1 dsov20gbwu bandwidth upgrade to 25 ghz 1 dsov25gbwu bandwidth upgrade to 33 ghz 1 dsov33gbwu memory upgrades description option number for existing oscilloscopes (post-sale) 50 to 100 mpts/channel memory upgrade n2810a-100 100 to 200 mpts/channel memory upgrade n2810a-200 200 to 500 mpts/channel memory upgrade n2810a-500 500 mpts/channel to 1 gpts/channel memory upgrade n2810a-01g 1 gpts/channel to 2 gpts/channel memory upgrade n2810a-02g other upgrades description option number for existing oscilloscopes (post-sale) hardware serial trigger upgrade 1, 2 n2119au mso upgrade 1, 2 n2118au additional 500 gb removable solid state drive (ssd) with windows 7 n2110a-500 additional 1 tb removable solid state drive (ssd) with windows 7 n2110a-01t gpib card-interface 82351b performance verification and deskew fixture n5443a stack mount kit option for stacking two frames n2117a rack mount n5470a testmobile scope cart 1180CZ 1 ? return to keysight service center is required to perform upgrade ? 2 ? either mso or hardware serial trigger option can be added to the oscilloscope ? upgrade is not available when the oscilloscope already has the mso or hardware serial trigger installed ? ordering configuration
34 | keysight | infiniium v-series oscilloscopes - data sheet vertical dso/dsa/mso models v084a v134a v164a v204a v254a v334a vertical - oscilloscope channels input channels dso/dsa models - 4 analog mso models - 4 analog + 16 digital analog bandwidth (3 db) 2 channel 1 2 channel (typical) 4 channel 1 4 channel (typical) 8 ghz 8.4 ghz 8 ghz 8.4 ghz 13 ghz 13.6 ghz 13 ghz 13.6 ghz 16 ghz 16.8 ghz 16 ghz 16.8 ghz 20 ghz 21 ghz 16 ghz 16.8 ghz 25 ghz 26.2 ghz 16 ghz 16.8 ghz 32 ghz 33 ghz 16 ghz 16.8 ghz rise time/fall time 10 to 90% 5 20 to 80% 6 55.0 ps 38.9 ps 33.8 ps 23.9 ps 27.5 p s 19.4 ps 22.0 ps 15.6 ps 17.6 p s 12.4 ps 13.3 ps 9.4 ps input impedance 2 50 ?, 3% input sensitivity 3 1 mv/div to 1 v/div full scale hardware sensitivity 60 mv to 8 v (oscilloscope only) 60 mv to 1.2 v (oscilloscope with n7010a voltage termination adapter) input coupling dc vertical resolution 3, 4 8 bits, 12 bits with high-resolution mode or averaging channel-to-channel isolation (any two channels with equal v/div settings) channel-to-channel: 1-3, 1-4, 2-3, and 2-4 dc to bw: 70 db channel-to-channel: 1-2 and 3-4 dc to 4 ghz: 50 db 4 to 12 ghz: 40 db 12 ghz to bw: 35 db dc gain accuracy 1, 2, 3, 4 2% of full scale at full resolution channel scale ( 2.5% for 5 mv/div) maximum input voltage 5 v offset range vertical sensitivity available offset available offset (oscilloscope with n7010a voltage termination adapter) 1 to 49 mv/div 0.4 v additional 4 v 50 to 79 mv/div 0.7 v additional 4 v 80 to 134 mv/div 1.2 v additional 4 v 135 to 239 mv/div 2.2 v additional 4 v 240 mv/div to 1 v/div 4.0 v additional 4 v offset accuracy 1 3.5 v: (2% of channel offset + 1% of full scale + 1 mv) > 3.5 v: (2% of channel offset + 1% of full scale) dynamic range 4 div from center screen dc voltage measurement accuracy dual cursor: [(dc gain accuracy) + (resolution)] single cursor: [(dc gain accuracy) + (offset accuracy) + (resolution/2)] 1 ? denotes warranted specifications, all others are typical ? specifications are valid after 30-minute warm up period and 5% from oscilloscope firmware calibration temperature ? 2 ? input impedance is valid when v/div scaling is adjusted to show all waveform vertical values within scope display ? 3 ? full scale is defined as eight vertical divisions ? magnification is used below 7 ? 5 mv/div ? below 7 ? 5 mv/div, full scale is defined as 60 mv/div ? the major scale settings are 1 mv/div, 2 mv/div, 5 mv/div, 10 mv/div, 20 mv/div, 50 mv/div, 100 mv/div, 200 mv/div, 500 mv/div and 1v/div ? 4 ? vertical resolution for 8 bits = 0 ? 4% of full scale, for 12 bits = 0 ? 024% of full scale ? 5 ? calculation based on tr = 0 ? 44/bw ? 6 ? calculation based on tr = 0 ? 31/bw ? infiniium v-series performance characteristics
35 | keysight | infiniium v-series oscilloscopes - data sheet rms noise floor (oscilloscope only) v084a v134a v164a v204a v254a v334a vertical setting (mvrms) 8 ghz 13 ghz 16 ghz 20 ghz 25 ghz 33 ghz 5 mv/div 0.21 mv 0.27 mv 0.31 mv 0.37 mv 0.45 mv 0.58 mv 10 mv/div 0.23 mv 0.28 mv 0.36 mv 0.42 mv 0.49 mv 0.60 mv 20 mv/div 0.46 mv 0.57 mv 0.65 mv 0.74 mv 0.83 mv 1.04 mv 50 mv/div 1.04 mv 1.09 mv 1.32 mv 1.54 mv 1.73 mv 2.09 mv 100 mv/div 1.92 mv 2.30 mv 2.63 mv 3.02 mv 3.39 mv 3.98 mv 200 mv/div 4.39 mv 5.52 mv 6.14 mv 6.92 mv 8.16 mv 9.88 mv 500 mv/div 10.07 mv 12.42 mv 13.68 mv 15.05 mv 17.0 8 mv 20.25 mv 1 v/div 18.47 mv 21.36 mv 26.12 mv 30.15 mv 34.36 mv 39.35 mv rms noise floor (with n7010a voltage termination adapter) vertical setting (mvrms) 8 ghz 13 ghz 16 ghz 20 ghz 25 ghz 30 ghz 5 mv/div 0.28 mv 0.41 mv 0.44 mv 0.51 mv 0.65 mv 0.84 mv 10 mv/div 0.30 mv 0.42 mv 0.48 mv 0.57 mv 0.70 mv 0.86 mv 20 mv/div 0.54 mv 0.74 mv 0.84 mv 0.99 mv 1.20 mv 1.48 mv 50 mv/div 1.21 mv 1.64 mv 1.86 mv 2.18 mv 2.64 mv 3.21 mv 100 mv/div 2.42 mv 3.25 mv 3.68 mv 4.30 mv 5.16 mv 6.21 mv 200 mv/div 4.84 mv 6.48 mv 7. 3 3 mv 8.53 mv 10.18 mv 12.18 mv 500 mv/div 12.16 mv 16.39 mv 18.64 mv 21.89 mv 26.42 mv 32.06 mv 1 v/div 24.21 mv 32.50 mv 36.80 mv 42.99 mv 51.55 mv 61.98 mv vertical - digital channels on all mso models input channels 16 digital channels threshold groupings two individual threshold settings (1 for channels 0 to 7 and 1 for channels 8 to 15) threshold selections ttl (1.4 v), cmos (2.5 v), ecl (1.3 v), pecl (3.7 v), custom ( 3.75 v in 10 mv increments) maximum input voltage 40 v peak cat i threshold accuracy (100 mv + 3% of threshold setting) input dynamic range 10 v about threshold minimum input voltage swing 200 mv peak-to-peak input impedance (flying leads) 20 k? 2% (~0.7 pf) at probe tip resolution 1 bit analog bandwidth 3 ghz (depends on probing) infiniium v-series performance characteristics (continued) effective number of bits (enob) (signal 80% of full scale) vertical setting 8 ghz 13 ghz 16 ghz 20 ghz 25 ghz 33 ghz 7 mv/div 5.9 5.7 5.5 5.4 5.1 5.0 10 mv/div 6.1 5.9 5.8 5.7 5.5 5.2 20 mv/div 6.3 6.1 6.0 5.8 5.6 5.4 50 mv/div 6.4 6.2 6.2 6.0 5.8 5.6 100 mv/div 6.6 6.4 6.2 6.0 5.8 5.6
36 | keysight | infiniium v-series oscilloscopes - data sheet infiniium v-series performance characteristics (continued) horizontal horizontal system: oscilloscope channels main timebase range 2 ps/div to 200 s/div main timebase delay range 0 s 200 s real time resolution 1 ps reference position continuously adjustable across horizontal display range zoom time base range 1 ps/div to current main time scale setting time scale accuracy 1, 8 (0.1 ppm initial + 0.1 ppm/year aging) oscilloscope channel de-skew range 1 ms range, 10 fs resolution intrinsic jitter 6 (sample clock jitter) acquired time range or delta-time interval internal reference external reference < 1 s (100 ns/div) 100 fs rms 100 fs rms 10 s (1 s/div) 200 fs rms 200 fs rms 100 s (10 s/div) 500 fs rms 200 fs rms 1 ms (100 s/div) 2 ps rms 500 fs rms inter-channel intrinsic jitter 3 100 fs rms inter-channel skew drift 3, 7 < 50 fs rms jitter measurement floor 2 C time interval error ( ) 2 2 ? i nt r i ns i c j i t t e r? ? n oi s e f l oor sl e w r at e + ? ? ? ? ? ? C period jitter ( ) 2 2 ? 2 ? ? n oi s e f l oor i nt r i ns i c j i t t e r sl e w r at e + ? ? ? ? ? ? ? C cycle-cycle/n-cycle jitter ( ) 2 2 ? 3 ? ? n oi s e f l oor i nt r i ns i c j i t t e r sl e w r at e + ? ? ? ? ? ? ? inter-channel jitter measurement floor 2, 3, 5 ( ) ( ) 2 2 2 ? ? ? ? ? ? 1 2 ? t i m e i nt e r v al t i m e i nt e r v al i nt e r c hanne l e r r or e dge e r r or e dge i nt r i ns i c j i t t e r + + ? ? ? ? ? ? ? ? ? ? ? ? ? ? ? ? ? ? 1 ? denotes warranted specifications, all others are typical ? specifications are valid after a 30-minute warm-up period and 5 c from firmware calibration temperature ? 2 ? sample rate at maximum ? noise and slew rate determined at fixed-voltage measurement threshold, near middle of signal ? displayed signal not vertically clipped ? slew rate of sine wave = (peak signal amplitude) 2 f, slew rate of fast step ~= (10 to 90% rise time) ? 3 ? intra-channel = both edges on the same channel, inter-channel = two edges on different channels ? time interval error(edge1) = time-interval error measurement floor of first edge, time interval error(edge2) = time-interval error measurement floor of second edge ? 4 ? reading is the displayed delta time measurement accuracy measurement value ? do not double the listed time scale accuracy value in delta time measurement accuracy formula ? 5 ? scope channels and signal interconnect de-skewed prior to measurement ? 6 ? external timebase reference values measured using a wenzel 501-04608a 10 mhz reference ? intrinsic jitter value depends on acquisition time range for time interval error formula and depends on delta-time between edges for all two-edge formulas ? 7 ? skew between channels caused by 5 c temperature change ? 8 ? initial = immediately after factory or user calibration ?
37 | keysight | infiniium v-series oscilloscopes - data sheet infiniium v-series performance characteristics (continued) horizontal (continued) horizontal system: oscilloscope channels (continued) delta time measurement accuracy 2, 3, 4, 5 C intra-channel C no averaging ( ) ( ) 2 2 ? ? ? ? ? ? ? 5 ? ? ? 1 2 ? t i m e i nt e r v al t i m e i nt e r v al t i m e sc al e d e l t a e r r or e dge e r r or e dge a c c ur ac y t i m e ? ? ? ? ? ? ? ? ? ? + + ? ? ? ? ? ? ? ? ? ? ? ? ? ? ? ? ? ? ? ? ? ? ? ? ? ? ? ? ? ? C 256 averages ( ) ( ) 2 2 ? ? ? ? ? ? ? 5 ? ? ? 1 2 ? 16 t i m e i nt e r v al t i m e i nt e r v al t i m e sc al e d e l t a e r r or e dge e r r or e dge a c c ur ac y t i m e ? ? ? ? ? ? ? ? ? ? ? ? ? ? + + ? ? ? ? ? ? ? ? ? ? ? ? ? ? ? ? ? ? ? ? ? ? ? ? ? ? C inter-channel C no averaging ( ) ( ) 2 2 2 ? ? ? ? ? ? 5 ? 1 2 ? ? ? ? ? ? ? ? ? ? t i m e i nt e r v al t i m e i nt e r v al i nt e r c hanne l e r r or e dge e r r or e dge i nt r i ns i c j i t t e r t i m e sc al e d e l t a i n t e r c h a n n e l a c c ur ac y t i m e sk e w d r i f t ? ? ? ? ? ? ? ? ? ? + + ? ? ? ? ? ? ? ? ? ? ? ? ? ? ? ? ? ? ? ? ? ? ? ? ? + + ? ? ? ? ? ? ? ? ? ? ? ? ? ? ? ? ? ? ? ? ? ? ? C 256 averages ( ) ( ) 2 2 2 ? ? ? ? ? ? 5 ? 1 2 ? 16 ? ? ? ? ? ? ? t i m e i nt e r v al t i m e i nt e r v al i nt e r c hanne l e r r or e dge e r r or e dge i nt r i ns i c j i t t e r t i m e sc al e d e l t a i n t e r c h a n n e l a c c ur ac y t i m e sk e w d r ift ? ? ? ? ? ? + + ? ? ? ? ? ? ? ? ? ? ? ? ? ? ? ? ? ? + + ? ? ? ? ? ? ? ? ? ? ? ? ? ? ? ? ? ? ? ? ? ? ? ? ? ? ? ? ? ? ? ? ? ? 2 ? sample rate at maximum ? noise and slew rate determined at fixed-voltage measurement threshold, near middle of signal ? displayed signal not vertically clipped ? slew rate of sine wave = (peak signal amplitude) 2 f, slew rate of fast step ~= (10 to 90% rise time) ? 3 ? intra-channel = both edges on the same channel, inter-channel = two edges on different channels ? time interval error(edge1) = time-interval error measurement floor of first edge, time interval error(edge2) = time-interval error measurement floor of second edge ? 4 ? reading is the displayed delta time measurement accuracy measurement value ? do not double the listed time scale accuracy value in delta time measurement accuracy formula ? 5 ? scope channels and signal interconnect de-skewed prior to measurement ?
38 | keysight | infiniium v-series oscilloscopes - data sheet acquisition acquisition - oscilloscope channels v084a v134a v164a v204a v254a v334a maximum real-time sample rate 2 channels 80 gsa/s 80 gsa/s 80 gsa/s 80 gsa/s 80 gsa/s 80 gsa/s 4 channels 40 gsa/s 40 gsa/s 40 gsa/s 40 gsa/s 40 gsa/s 40 gsa/s memory depth per channel 4 channels 2 channels standard 50 mpts 100 mpts option 100 (standard on dsa model) 100 mpts 200 mpts option 200 200 mpts 500 mpts option 500 500 mpts 1 gpts option 01g 1 gpts 1 gpts option 02g 2 gpts 2 gpts maximum acquired time at highest real-time resolution 40 gsa/s 80 gsa/s standard 1.25 ms 1.25 ms option 100 (standard on dsa model) 2.5 ms 2.5 ms option 200 5 ms 5 ms option 500 12.5 ms 12.5 ms option 01g 25 ms 12.5 ms option 02g 50 ms 25 ms maximum waveform update rate > 400,000 waveforms per second (when in segmented memory mode) infiniium v-series performance characteristics (continued) sampling modes - oscilloscope channels real-time successive single shot acquisitions real-time with averaging averages are selectable from 2 to 65,534 real-time with peak detect 80 gsa/s in 2-channel mode, 40 gsa/s in 4-channel mode real-time with hi-resolution real-time boxcar averaging reduces random noise and increases resolution equivalent time resolution 338 fs gaussian magnitude, linear phase slow filter roll off while maintaining linear phase roll mode scrolls sequential waveform points across the display in a right-to-left rolling motion. works at sample rates up to 10 msa/s with a maximum record length of 40 mpts. segmented memory captures bursting signals at maximum sample rate without consuming memory during periods of inactivity. C maximum time between triggers is 562,950 seconds C re-arm time: 2.5 s memory depth: 20 m 50 m 100 m 200 m 500 m 1 g 2 g max # of segments: 4096 8192 16384 32768 65536 131072 131072 filters - sin(x)/x interpolation on/off selectable fir digital filter. digital signal process adds points between acquired data points to enhance measurement accuracy and waveform display. acquisition - digital channels maximum real-time sample rate 10 gsa/s with 16 channels, 20 gsa/s with 8 channels maximum memory depth per channel up to 1 gpts minimum width glitch detection 50 ps
39 | keysight | infiniium v-series oscilloscopes - data sheet trigger trigger - oscilloscope channels trigger sources channel 1, channel 2, channel 3, channel 4, and aux sensitivity internal low: 2.0 div p-p for 0 to 22 ghz internal high: 0.3 div p-p for 0 to 18 ghz, 1.0 div p-p for > 18 to 22 ghz auxiliary: 2.5 ghz edge trigger bandwidth > 20 ghz minimum pulse width trigger hardware software (infniiscan) 250 ps 40 ps level range internal auxiliary 4 div from center screen or 4 v, whichever is smaller 5 v, also limit input signal to 5 v sweep modes auto (continuous), triggered, single, segmented display jitter 2, 3, 4 (trigger jitter) 230 fs rms trigger holdoff range 100 ns to 10 s trigger qualification (and qualifier) single and multiple channels may be logically qualified with any other trigger mode trigger actions specify an action to occur (and the frequency of the action) when a trigger conditions occurs. actions include email on trigger and execute "multipurpose" user setting. trigger sequences three stage trigger sequences including two-stage hardware (find event (a) and trigger event (b)) and one-stage infiniiscan software trigger. supports all hardware trigger modes except edge then edge and video and "gbit serial." supports delay (by time) and reset (by time or event) between two hardware sequences. the minimum latency between find event (a) and trigger event (b) is 3 ns. trigger - digital channels mso models threshold range (user-defined) 3.75 v in 10 mv increments threshold accuracy (100 mv + 3% of threshold setting) protocol triggering all mso models come standard with protocol trigger for ddr, lpddr, ddr2, lpddr2, ddr3, lpddr3, ddr4, and lpddr4 1 ? denotes warranted specifications, all others are typical ? specifications are valid after a 30-minute warm-up period and 5 c from firmware calibration temperature ? 2 ? internal edge trigger mode with jitterfree correction ? value depends on scope settings and trigger signal characteristics, and is equal to tie value expressed in the formula above using the minimum time scale accuracy value ? 3 ? value shown represents typical display jitter for dsov164a at 100 mv/div triggering on 500 mvpp 8 ghz sin wave signal ? 4 ? sample rate at maximum ? noise and slew rate determined at fixed-voltage trigger threshold, near middle of signal ? displayed signal not vertically clipped ? infiniium v-series performance characteristics (continued)
40 | keysight | infiniium v-series oscilloscopes - data sheet trigger (continued) trigger mode - hardware edge (analog and digital) triggers on a specified slope (rising, falling or alternating between rising and falling) and voltage level on any channel or auxiliary trigger edge transition (analog) triggers on rising and falling edges that cross two voltage levels in > or < the amount of time specified. edge transition setting from 250 ps edge then edge (time) (analog and digital) the trigger is qualified by an edge. after a specified time delay between 10 ns to 10 s, a rising or falling edge on any one selected input will generate the trigger edge then edge (event) (analog and digital) the trigger is qualified by an edge. after a specified delay between 1 to 16,000,000 rising or falling edges, another rising or falling edge on any one selected input will generate the trigger glitch (analog and digital) trigger on glitches narrower than the other pulses in your waveform by specifying a width less than your narrowest pulse and a polarity. trigger on glitches as narrow as 125 ps (analog only). glitch range settings from 250 ps to 10 s pulse width (analog and digital) triggers on a pulse width that is wider or narrower than the other pulses in your waveform by specifying a pulse width and a polarity. trigger on pulse widths as narrow as 125 ps (analog only). pulse width range settings from 250 ps to 10 s. trigger point can be "end of pulse" to "time out" runt (analog) triggers on a pulse that crosses one threshold but fails to cross a second threshold before crossing the first again. can be time qualified with minimum setting of 250 ps timeout (analog and digital) triggers when a channel stays high, low or unchanged for too long. timeout settings from 250 ps to 10 s pattern (analog and digital) triggers when a specified logical combination of the channels is entered, exited or present for a specified period of time or is within a specified time range or times out. each channel can have a value of high (h), low (l), or don't care (x) state (analog and digital) pattern trigger clocked by rising, falling, or alternating between rising and falling edge of one channel setup and hold (analog) trigger on setup, hold or setup and hold violations in your circuit. requires a clock and data signal on any two inputs (except aux or line) channels as trigger sources. setup and/or hold time must then be specified window (analog) triggers on an event associated with a window defined by two-user adjustable thresholds. event can be window "entered," "exited," "inside (time qualified)" or "outside (time qualified)" voltage range. trigger point can be "cross window boundary" or "time out." time qualify range from 250 ps to 10 s gbit serial (analog) 1 triggers on bit patterns at rates from 480 mb/s to 12.5 gb/s generic mode - trigger up to 160-bit sequence of arbitrary nrz data (high, low, dont care) 8b/10b mode - trigger up to 10 k and d code symbols. alignment character is k28.5 (either disparity) prbs errors mode - count accumulated bits and errors, and trigger bit error for prbs 7, 15, 23, and 31 video (analog) triggers from negative sync composite video, field 1, field 2, or alternating fields for interlaced systems, any field, specified line or any line for interlaced or non-interlaced systems. support ntsc, pal-m (525/60), pal, secam (625/50), edtv (480p/60), edtv (576p/50), hdtv (720p/60), hdtv (720p/50), hdtv (1080i/60), hdtv (1080i/50), hdtv (1080p/60), hdtv (1080p/50), hdtv (1080p/30), hdtv (1080p/25), hdtv (1080p/24) and user-defined formats trigger mode - software infiniiscan event identification software zone qualify software triggers on the user-defined zones on screen. zones can be specified as either must intersect or must not intersect. up to eight zones can be defined across multiple channels generic serial software triggers on nrz-encoded data up to 80-bit pattern. support multiple clock data recovery methods including constant frequency, 1st-order pll, 2nd-order pll, explicit clock, explicit 1st-order pll, explicit 2nd-order pll, fibre channel, flexray receiver, flexray transmitter (requires e2688a except for the constant frequency clock data recovery mode) measurement limit software triggers on the results of the measurement values. for example, when the pulse width measurement is turned on, infiniiscan measurement software triggers on a glitch as narrow as 40 ps. when the time interval error (tie) is measured, infiniiscan can trigger on a specific tie value non-monotonic edge software triggers on the non-monotonic edge. the non-monotonic edge is specified by setting a hysteresis value runt software triggers on a pulse that crosses one threshold but fails to cross a second threshold before crossing the first again. unlike hardware runt trigger, infiniiscan runt trigger can be further qualified via a hysteresis value protocol require specified protocol option (i 2 c, spi, can, lin, rs-232/uart, svid, usb, pcie, sata, sas, mipi, ethernet, 10g-kr, dvi/hdmi, xaui, and generic 8b/10b) 1 ? models with hardware serial trigger option ? infiniium v-series performance characteristics (continued)
41 | keysight | infiniium v-series oscilloscopes - data sheet measurements and math oscilloscope measurements number of measurements 20 simultaneous measurements (can be made on either main, zoom or gated region) measurement update rate > 50,000 measurement/sec (one measurement turned on) > 250,000 measurement/sec (10 measurements turned on) measurement access drop down measurement list measurement menu access to all measurements multipurpose front panel button activates up to 10 pre-selected or up to 10 user-defined measurements drag-and-drop measurement toolbar measurement toolbar with common measurement icons that can be dragged and dropped onto the displayed waveforms measurement modes statistics displays the current, mean, minimum, maximum, range (max-min), standard deviation, count, edge, direction, meas window, icon x, and icon y histograms source waveform or measurement orientation vertical (for timing and jitter measurements) or horizontal (noise and amplitude change) modes, regions are defined using waveform markers measurements mean, standard deviation, mean 1, 2, and 3 sigma, median, mode, peak-to-peak, min, max, total hits, peak (area of most hits), x scale hits, and x offset hits marker modes manual markers, track waveform data, track measurements, and delta marker values can be displayed waveform measurements voltage (analog) peak-to-peak, minimum, maximum, average, rms, amplitude, base, top, overshoot, preshoot, v overshoot, v preshoot, upper, middle, lower, crossing point voltage, pulse top, pulse base, pulse amplitude time (analog) rise time, fall time, period, frequency, positive width, negative width, duty cycle, tmin, tmax, tvolt, channel-to-channel delta time, channel-to-channel phase, count pulses, burst width, burst period, burst interval, setup time, hold time, edge-edge, edge time, slew rate time (digital) period, frequency, positive width, negative width, duty cycle, delta time clock (analog) period, frequency, duty cycle, clock, phase, tie 1 , n-period 1 , period-period 1 , + width to + width 1 , - width to - width 1 , duty cycle- to-duty cycle data (analog) setup time, hold time , time interval error 1 , unit interval, noise, n-ui, ui-ui, data rate, clock recovery rate, ddpws, de-emphasis mixed (analog) area, slew rate frequency domain (analog) fft frequency, fft magnitude, fft delta frequency, fft delta magnitude, peak detect mode, amplitude modulation eye (analog) eye height, eye width, eye jitter, crossing %, q factor, duty cycle distortion level qualifcation any channels that are not involved in a measurement can be used to level-qualify all timing measurements 1 ? requires ezjit plus (option n5400a) or ezjit complete (option n8823a) software ? infiniium v-series performance characteristics (continued)
42 | keysight | infiniium v-series oscilloscopes - data sheet measurements and math (continued) oscilloscope measurements eye-diagram measurements 1 eye height, eye width, eye jitter, crossing percentage, q factor, and duty-cycle distortion jitter analysis measurements 2 clock time interval error, n-period, period to period, + width to + width, - width to - width, and duty cycle-to- duty cycle data random jitter (rj), deterministic jitter (dj), aperiodic bounded uncorrelated jitter (abuj), periodic jitter (pj), data dependent jitter (ddj), duty cycle distortion (dcd), intersymbol interference (isi) jitter separation spectral method (rj narrow and wide), tailfit rj setting ability to fix random jitter (rj) for crosstalk measurements mask testing allows pass/fail testing to user-defined or keysight-supplied waveform templates. automask lets you create a mask template from a captured waveform and define a tolerance range in time/voltage or screen divisions. test modes (run until) include test forever, test to specified time or event limit, and stop on failure. executes multipurpose user setting on failure. unfold real-time eye feature will allow individual bit errors to be observed by unfolding a real-time eye when clock recovery is on. communications mask test kit option provides a set of itu-t g.703, ansi t1.102, and ieee 802.3 industry-standard masks for compliance testing. math functions waveform math number of functions up to 16 independent functions number of gating functions up to 16 horizontal measurement gates (any function can be used as a gate) math source any combination of channels, memories or other functions hardware accelerated math differential and common mode (analog) operators absolute value, add, am demodulation, average, butterworth 1 , common mode, delay, differentiate, divide, envelope, fft magnitude, fft phase, fir 1 , gating, high pass filter, histogram, integrate, invert, lfe 1 , low pass filter (4th-order bessel thompson filter), magnify, max, meas trend, min, multiply, rt eye 1 , smoothing, sqrtsumofsquare 1 , square, square root, subtract, versus, chart (mso models) and user-defined function 3, 4 fft frequency range dc to 40 ghz (at 80 gsa/s) or 20 ghz (at 40 gsa/s) frequency resolution resolution = sample rate/memory depth window modes hanning, flattop, rectangular, blackman-harris, hamming number of ffts display up to 16 ffts, each in their own grid with up to eight in their own waveform area peak mode choose peak callouts to display peak values on the screen 1 ? requires serial data analysis (option e2688a) software ? 2 ? requires ezjit plus (option n5400a) or ezjit complete (option n8823a) software ? 3 ? requires matlab (option n8831a) software ? 4 ? requires user-defined function (option n5430a) software ? infiniium v-series performance characteristics (continued)
43 | keysight | infiniium v-series oscilloscopes - data sheet display, computer system, i/o ports, and file types display display 12.1-inch color xga tft-lcd with capacitive touch screen intensity grayscale 256-level intensity-graded display resolution xga 1024 pixels horizontally x 768 pixels vertically annotation up to 100 bookmarks can be inserted into the waveform window. each can float or be tied to a specific waveform grids up to 16 waveform grids, each with 8-bit vertical resolution waveform windows up to eight individual waveform windows, allowing up to 128 viewing spaces waveform styles connected dots, dots, infinite persistence, variable persistence, color-graded infinite persistence. includes up to 256 levels of intensity-graded waveforms. computer system and peripherals operating system windows 7 64-bit cpu intel core i5-3550s quad core cpu at 3.00 ghz pc system memory 16 gb ddr3 ram storage drive standard 500 gb removable ssd optional 1 tb removable ssd (option 801) peripherals optical usb mouse and compact keyboard supplied. all infiniium models support any windows-compatible input device with a usb interface lxi compliance lxi class c infiniium v-series performance characteristics (continued)
44 | keysight | infiniium v-series oscilloscopes - data sheet display, computer system, i/o ports, and file types (continued) i/o ports ethernet (lan) rj-45 connector, supports 10base-t, 100base-t, and 1000base-t. enables web-enabled remote control, email on trigger, data/file transfers, and network printing usb 8 total ports C front panel: two usb 3.0 host ports and one usb 2.0 host port C back panel: two usb 3.0 host ports, one usb 3.0 device port and two usb 2.0 ports C usb 3.0 port supports up to 200 mb/s data offload external display two ports: one displayport and one vga video out drivers support up to two simultaneous displays gpib ieee-488 digital communication bus for instrument control oscilloscope ports auxiliary out 100 mhz, square wave, prbs 2 7 -1, prbs 2 15 -1, prbs 2 23 -1, and prbs 2 31 -1 calibration out dc ( 2.4 v), 100 mhz, square wave, prbs 2 7 -1, prbs 2 15 -1, prbs 2 23 -1, and prbs 2 31 -1 trigger out peak-to-peak amplitude into 50 ?: 2.4 v, offset: 0 v time base reference output peak-to-peak amplitude into 50 ?: 750 mv, offset: 0 v when derived from the internal reference signal amplitude follows reference input when derived from external reference time base external reference input (impedance into 50 ?) amplitude: 178 mv peak to 1 v peak frequency: 10 mhz 5 ppm high-quality sine wave or square wave auxiliary trigger in external trigger input digital channels connector 1 digital channel inputs pattern generator 2 demo pattern output from the hardware serial trigger peak-to-peak amplitude into 50 ?: 400 mv, offset: 400 mv reference clock in 2 external clock reference input to the hardware serial trigger peak-to-peak amplitude: 0.8 v to 3.6 v. voltage range: 0.1 v to 3.7 v clock rise and fall time (10 to 90%): 1 ns or faster recovered clock out 2 sub-rate clock output generated by the hardware serial trigger peak-to-peak amplitude into 50 ?: 1 v, offset: 0 v file types analog waveform compressed internal format (*.wfm (200 mpts)) comma-separated values (*.csv (2 gpts)) tab separated values (*.tsv (2 gpts)) public binary format (*.bin (500 mpts)) y value file (*.txt (2 gpts)) hierarchical data file (*.h5 (2 gpts)) composite setup and data file (*.osc (2 gpts)) digital waveform hierarchical data file (*.h5 (2 gpts)) composite setup and data file (*.osc (2 gpts)) images bmp, png, tiff, gif, or jpeg 1 ? mso models only ? 2 ? models with hardware serial trigger option ? infiniium v-series performance characteristics (continued)
45 | keysight | infiniium v-series oscilloscopes - data sheet general and environmental general characteristics temperature operating: 5 to +40 c non-operating: 40 to +65 c humidity operating: up to 95% relative humidity (non-condensing) at +40 c non-operating: up to 90% relative humidity at +65 c altitude operating: up to 4,000 meters (12,000 feet) non-operating: up to 15,300 meters (50,000 feet) vibration operating random vibration 5 to 500 hz, 10 minutes per axis, 0.21 g(rms) non-operating random vibration 5 to 500 hz, 10 minutes per axis, 2.0 g(rms); resonant search 5 to 500 hz swept sine, 1 octave/minute sweep rate, (0.50 g), 5 minute resonant dwell at 4 resonances per axis power 100 to 240 vac at 50/60 hz; input power 800 watts weight frame: 52.2 lbs. (23.7 kg); shipping: 71.7 lbs. (32.5 kg) dimensions height: 10.5 in (26.6 cm); width: 17.2 in (43.6 cm); depth: 19.4 in (49.2 cm) safety iec 61010-1:2010/en 61010-1 3rd edition can / csa22.2 no. 61010-1-12 ul std. 61010-1 (3rd edition) pollution degree 2 installation category 2 measurement category 1 environment for indoor use only infiniium v-series performance characteristics (continued)
46 | keysight | infiniium v-series oscilloscopes - data sheet www.axiestandard.org advancedtca ? extensions for instrumentation and test (axie) is an open standard that extends the advancedtca for general purpose and semiconductor test? the business that became keysight was a founding member of the axie consortium? atca ? , advancedtca ? , and the atca logo are registered us trademarks of the pci industrial computer manufacturers group? www.lxistandard.org lan extensions for instruments puts the power of ethernet and the web inside your test systems? the business that became keysight was a founding member of the lxi consortium? www.pxisa.org pci extensions for instrumentation (pxi) modular instrumentation delivers a rugged, pc-based high-performance measurement and automation system? learn more at www ? keysight ? com/find/software start with a 30-day free trial ? www ? keysight ? com/find/free_trials download your next insight keysight software is downloadable expertise ? from first simulation through first customer shipment, we deliver the tools your team needs to accelerate from data to information to actionable insight ? C electronic design automation (eda) software C application software C programming environments C productivity software
47 | keysight | infiniium v-series oscilloscopes - data sheet this information is subject to change without notice? ? keysight technologies, 2015 - 2017 published in usa, december-1 1, 2017 5992-0425en www?keysight?com for more information on keysight technologies products, applications or services, please contact your local keysight office? the complete list is available at: www?keysight?com/find/contactus americas canada (877) 894 4414 brazil 55 11 3351 7010 mexico 001 800 254 2440 united states (800) 829 4444 asia pacific australia 1 800 629 485 china 800 810 0189 hong kong 800 938 693 india 1 800 11 2626 japan 0120 (421) 345 korea 080 769 0800 malaysia 1 800 888 848 singapore 1 800 375 8100 taiwan 0800 047 866 other ap countries (65) 6375 8100 europe & middle east austria 0800 001122 belgium 0800 58580 finland 0800 523252 france 0805 980333 germany 0800 6270999 ireland 1800 832700 israel 1 809 343051 italy 800 599100 luxembourg +32 800 58580 netherlands 0800 0233200 russia 8800 5009286 spain 800 000154 sweden 0200 882255 switzerland 0800 805353 opt? 1 (de) opt? 2 (fr) opt? 3 (it) united kingdom 0800 0260637 for other unlisted countries: www?keysight?com/find/contactus (bp-9-7-17) dekra certified iso9001 quality management system www?keysight?com/go/quality keysight technologies, inc? dekra certified iso 9001:2015 quality management system evolving since 1939 our unique combination of hardware, software, services, and people can help you reach your next breakthrough ? we are unlocking the future of technology ? from hewlett-packard to agilent to keysight ? mykeysight www?keysight?com/find/mykeysight a personalized view into the information most relevant to you? http://www?keysight?com/find/emt_product_registration register your products to get up-to-date product information and find warranty information? keysight services www?keysight?com/find/service keysight services can help from acquisition to renewal across your instruments lifecycle? our comprehensive service offeringsone- stop calibration, repair, asset management, technology refresh, consulting, training and morehelps you improve product quality and lower costs? keysight assurance plans www?keysight?com/find/assuranceplans up to ten years of protection and no budgetary surprises to ensure your instruments are operating to specification, so you can rely on accurate measurements? keysight channel partners www?keysight?com/find/channelpartners get the best of both worlds: keysights measurement expertise and product breadth, combined with channel partner convenience?